fix: precision leaves 1000 kB in the old unit and rounds to round before the unit bump #413
Two problems in the precision path when the value moves to the next unit (applyPrecisionHandling):
Since 11.0.31 (fix: apply precision before round for decimal units #404), a value that rounds up to the unit ceiling stays in the old unit: filesize(999999, { precision: 4 }) prints 1000 kB, while filesize(999999) prints 1 MB. 11.0.30 printed 1.000 MB. The unit only moves when toPrecision() returns e-notation, and (999.999).toPrecision(4) is "1000".
When the unit does move, the new value is rounded to round decimals before toPrecision() runs. This is the same double rounding fix: precision is applied after round, rounding an already-rounded value #399 fixed in the main path. With round: 0 it even prints 0: filesize(392, { precision: 1, round: 0 }) gives 0 kB.
In applyPrecisionHandling() (src/helpers.js) the bump runs only on result.includes(E), and the recomputed value goes through roundingFunc(valueResult * p) / p before toPrecision(). The existing test "should handle precision with specific test case for GiB values" pins 0.990 GiB, but 1058223158 / 2^30 = 0.98555. I have a fix ready and will open a PR.