113 changes: 110 additions & 3 deletions test_blockserver.py
Original file line number Diff line number Diff line change
@@ -1,21 +1,25 @@
import json
import os
import socket
import time
import unittest
import zlib
from itertools import product

import requests
from genie_python import genie as g
from genie_python.channel_access_exceptions import UnableToConnectToPVException
from genie_python.utilities import compress_and_hex
from genie_python.genie_cachannel_wrapper import CaChannelWrapper, AlarmCondition
from genie_python.utilities import compress_and_hex, dehex_and_decompress
from hamcrest import assert_that, contains_string, ends_with, is_
from parameterized import parameterized

from utilities import utilities
from utilities.utilities import assert_with_timeout, parameterized_list

Check failure on line 18 in test_blockserver.py

View workflow job for this annotation

GitHub Actions / call-workflow / ruff

ruff (I001)

test_blockserver.py:1:1: I001 Import block is un-sorted or un-formatted help: Organize imports

SECONDS_TO_WAIT_FOR_IOC_STARTS = 120

SERVICE_RESTART_TIMEOUT = 180
NO_RESTART_GRACE_PERIOD = 15

def wait_for_server():
status_was_busy = False
Expand Down Expand Up @@ -141,7 +145,7 @@
"CAENV895 ioc should have restarted",
)
break
except (Exception, AssertionError) as e:
except AssertionError as e:
err = e
time.sleep(1)
else:
Expand Down Expand Up @@ -516,3 +520,106 @@
test_pv_with_macro_value(expected_1, "SIMPLE:MACROTEST1", self)
test_pv_with_macro_value(expected_2, "SIMPLE:MACROTEST2", self)
test_pv_with_macro_value(expected_3, "SIMPLE:MACROTEST3", self)

@parameterized.expand(
parameterized_list(
list(
product(
[
# (PV to monitor, service IOC to restart, values which indicate a restart)
# A CA disconnect on the monitored PV always counts as a restart.
("CS:PS:RUNCTRL_01:STATUS", "RUNCTRL_01", ("Shutdown",)),
# The blockserver serves this PV itself, so it disconnects on restart
("CS:BLOCKSERVER:SERVER_STATUS", "BLOCKSVR", ()),
("CS:PS:ISISDAE_01:STATUS", "ISISDAE_01", ("Shutdown",)),
("CS:PS:INSTETC_01:STATUS", "INSTETC_01", ("Shutdown",)),
("CS:PS:ALARM:STATUS", "ALARM", ("Shutdown",)),
("CS:PS:ARINST:STATUS", "ARINST", ("Shutdown",)),
("CS:PS:ARBLOCK:STATUS", "ARBLOCK", ("Shutdown",)),
# No blockgateway as this is not restarted in the typical sense, just "reloaded"
],
[True, False],
)
)
)
)
def test_WHEN_restart_service_ioc_pv_written_THEN_restarts_service(
self, _, pv_ioc_markers, manager
):
restarted = "RESTARTED"
events = []
pv, ioc, restart_markers = pv_ioc_markers
full_pv = g.prefix_pv_name(pv)

def _on_change(value, severity, status):
if status == AlarmCondition.Link:
events.append(restarted)
return
text = str(value)
try:
text = dehex_and_decompress(text)
except (ValueError, zlib.error):
pass
events.append(restarted if text in restart_markers else text)

def _restarted_and_came_back() -> bool:
# Need a value before the restart and at least one after it (i.e. it came back)
return restarted in events and 0 < events.index(restarted) < len(events) - 1

# Make sure a previous test's restart has fully finished before we start monitoring
self._wait_for_service_ready(ioc)

unsubscribe = CaChannelWrapper.add_monitor(
full_pv, _on_change, to_string=True, use_numpy=False
)
self.addCleanup(unsubscribe)
self._set_manager_mode(manager)

g.set_pv(
"CS:BLOCKSERVER:RESTART_SERVICE_IOC",
compress_and_hex(json.dumps([ioc])),
is_local=True,
)

if manager:
end_time = time.time() + SERVICE_RESTART_TIMEOUT
while time.time() < end_time and not _restarted_and_came_back():
time.sleep(0.5)
self.assertTrue(
_restarted_and_came_back(),
f"{ioc} did not restart and come back, events seen on {pv}: {events}",
)
# procServ reports "Running" as soon as the process is launched, but the service
# may not be serving PVs yet (e.g. INSTETC serves CS:MANAGER, which cleanup resets)
self._wait_for_service_ready(ioc)
else:
time.sleep(NO_RESTART_GRACE_PERIOD)
self.assertNotIn(
restarted, events, f"{ioc} restarted without manager mode, events: {events}"
)

@staticmethod
def _service_is_ready(ioc: str) -> bool:
try:
if ioc == "BLOCKSVR":
return utilities.get_server_status() == ""
if ioc in ("RUNCTRL_01", "ISISDAE_01", "INSTETC_01"):
# EPICS IOCs: heartbeat only exists once iocInit has completed
return utilities.is_ioc_up(ioc)
# Non-EPICS services (java processes) have no heartbeat, procServ status is all we have
return g.get_pv(f"CS:PS:{ioc}:STATUS", is_local=True) == "Running"
except UnableToConnectToPVException:
return False

def _wait_for_service_ready(self, ioc: str) -> None:
end_time = time.time() + SERVICE_RESTART_TIMEOUT
while time.time() < end_time:
if self._service_is_ready(ioc):
return
time.sleep(1)
self.fail(f"{ioc} was not ready after {SERVICE_RESTART_TIMEOUT}s")

def _set_manager_mode(self, manager: bool) -> None:
previous = g.get_pv("CS:MANAGER", is_local=True)
self.addCleanup(g.set_pv, "CS:MANAGER", previous, wait=True, is_local=True)
g.set_pv("CS:MANAGER", "Yes" if manager else "No", wait=True, is_local=True)
Loading